| Parameters |
Specifications |
| Wavelength Range |
1570 – 1610nm, L-band single channel |
| Gain Flattening Filter |
Not included |
| Output Power |
+36 dBm, tested with 1590 nm, +6 dBm input |
| Gain |
30 dB, tested with 1590 nm, +6 dBm input |
| Optical Input Fiber |
900um loose tube, FC/APC, blue, 1 meter, SMF-28 |
| Optical Output Fiber |
900um loose tube, FC/APC, red, 1 meter, SMF-28 |
| Input Power Monitoring Range |
-10 dBm to +10 dBm |
| Output Power Monitoring Range |
+15 to +37 dBm |
| Input Power Measurement Accuracy |
≤ +/- 0.5 dB, 1590 nm |
| Output Power Measurement Accuracy |
≤ +/- 0.5 dB, 1590 nm |
| Noise Figure |
≤ 7 dB, tested at 30 dB gain, 1590 nm, +6 dBm input |
| Control and Communication Interface |
RS-232, RS232 Voltage Level |
| Dimension |
200 x 100 x 49 mm |
| Power Input |
+24 VDC +/- 5% |
| Electrical Interface Connector |
PN: 173-E25-113R001 Male 25-PIN |
| Operational Case Temperature Range |
0 to +60 0C |
| Mode of Operation |
ACC (constant pump current control) |